– 43 –
Item
18. QUIET mode
Operation flow and applicable data, etc.
When the [QUIET] button is pressed, the fan of
the indoor unit will be restricted the revolving
speed at speed L - until the [QUIET] button is
pressed once again (cancel Quiet mode).
Description
Quiet mode is the system which, control the
revolving speed of indoor fan to work constantly
at lower than speed L. In addition, noise level of
indoor unit is less than usual.
Remarks :
1. Quiet mode is unable to work in dry mode.
2. Quiet mode is appropriate to work with less
cooling load and less heating load condition.
Because of the fan speed L- may cause not
enough the cooling capacity or heating
capacity.
The principles of comfort sleep mode are:
• Quietness for more comfortable. When room
temperature reach setting temperature
• Save energy by changing room temperature
automatically.
• The air condition can shut down by itself
automatically.
Remarks:
1. Comfort sleep mode will not operate in dry
mode and fan only mode.
Cooling mode
• The preset temperature will increase as
shown on ECO operation (Item No. 9)
• Press the [COMFORT SLEEP] button to
choose the operating hours.
Repeat pressing to select the hours.
(1hr, 3hr, 5hr or 9hr)
• If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
Heating mode
• The preset temperature will drop down as
shown on ECO operation (Item No. 9)
• Press the [COMFORT SLEEP] button to
choose the operating hours.
Repeat pressing to setect the hours.
(1hr, 3hr, 5hr or 9hr)
• If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
19. COMFORT
SLEEP
20. Short Timer
FILE NO. SVM-13004
Purpose
To start the unit immediately for the
purpose of testing, trial...etc, short timer
can be used maintenance of the unit.
Short Timer Setting
Q
Push [ ] button to turn the unit OFF.
R
Set the operation mode or plasma air
purifier on the remote controller without
sending the signal to the unit.
S
Use the tip of the pencil to push the
[CHK] button and hold, “00” will show
on display, then push [SET] button to
make "00" disappear.
T
Push [ ] button to turn the unit ON.
U
When short timer is activated, all setting
on the remote controller operates
immediately, besides, all indicatiors on
front panel turn ON continuously for
3 seconds.
In the normal condition, after switching one
circuit breaker, 3-minute delay time for
compressor and 1 hour for plasma air purifier
are set for the maintenance of the unit.
1
2
SWING
FA N
FIX
QUIET
Hi POWER
ONE-T
OUCH
COMFOR
T
SLEEP