– 11 –
FILE NO. SVM-01010
1 Compressor
2 Fan motor (for outdoor)
3
Running capacitor
(for fan motor)
4
Running capacitor
(for compressor)
5 Bimetal thermostat
6 Magnetic switch
4-1. Indoor Unit
4-2. Outdoor Unit (RAS-24UAX, RAS-24UA-AR)
No. Parts name Type Specifications
Red-Black White-Black
1.07 2.20
No. Parts name Type Specifications
1 Fan motor (for indoor) ICF-340-30-2 Output (Rated) 30W, 220-240V
2
Thermo sensor
——— 10k at 25°C
(TA-sensor)
3 DC-DC transformer (T01) SWT-58A DC 390V, Secondary DC 15V, 12V, 7V
4 Microcomputer TMP87CM40AN
5
Heat exchanger sensor
——— 10k at 25
°
C
(TC-sensor)
6 Line filter (L01) SS11V-R07190 19mH, AC 0.7A
7 Diode (DB01) D3SBA60 4A, 600V
8 Capacitor (C02) KMH450VNSN120M25C 120µF, 450V
9 Fuse (F01) TSCR T6.3A, 250V
10
Relay (for outdoor fan motor,
AJQ1341 Coil DC 12V, 33mA, Rated 1A, AC 250V
solenoid coil) (RY04)
11 Power supply IC (IC01) MA8920 5A, 900V
12 Varistor (R21, R22) 15G561K 560V
13 Resistor (R01) RF-5TK4R7 4.7 , 5W
14 Louver motor MP35EA12 Output (Rated) 2W,10poles, 1phase, DC 12V
4. SPECIFICATION OF ELECTRICAL PARTS
PA290X3F-4MS
MMF-230-65C
SK45FMP
SK42CMP45U1
CS-7C
CLK-35J
Output (Rated) 2200W, 2poles, 1phase, 220 – 240V, 50Hz
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65W, 6poles,1phase, 220 – 240V, 50Hz
Winding resistance (Ω)
(at 20°C)
AC 450V, 3.5µF
AC 420V, 45µF
Open 130 ± 5°C, Close 70 ± 10°C
220 – 240V, 50Hz
Red-Black White-Black
71.2 139.0