– 36 –
FILE NO. SVM-01010
8-6. Others
8-6-1. Gas leak test
Fig. 8-6-1
• Check the flare nut connections, valve stem cap
connections and service port cap connections for
gas leak with a leak detector or soap water.
8-6-2. Test operation
To switch the TEST RUN (COOL) mode, press
TEMPORARY button for 10 sec.
(The beeper will make a short beep.)
Service cap
connection
Valve stem cap
connection
Flare nut connections
(Outdoor unit)
Electric parts cover
Flare nut connections
(indoor unit)
Valve stem cap
connection
Fig. 8-6-2
D
C
A
B
TEMPORARY button
8-6-3. Auto restart setting
This product is designed so that, after a power failure,
it can restart automatically in the same operating mode
as before the power failure.
Information
The product was shipped with Auto Restart func-
tion in the off position. Turn it on as required.
<How to set the auto restart>
• Press and hold down the TEMPORARY button for
about 3 seconds. After 3 seconds, the electronic
beeper makes three short beeps to tell you the Auto
Restart has been selected.
• To cancel the Auto Restart, follow the steps
described in the section Auto Restart Function of
the Owner’s Manual.