– 26 –
FILE NO. SVM-01010
600 mm
340 mm
64 mm
120 mm
600 mm
120 mm
325 mm
52 mm
8-3. Installation
8-3-1. Optional installation parts
Air inlet
Air outlet
Air inlet
Air outlet
<Fixing bolt arrangement of outdoor unit>
RAS-18UAX / RAS-18UA-AR
Fig. 8-3-1
RAS-24UAX / RAS-24UA-AR
Fig. 8-3-2
Part
Code
A
B
C
Q'ty
One
each
1
One
each
Parts name
Refrigerant piping
Liquid side : 6.35 mm
Gas side : 12.70 mm (RAS-18UK)
: 15.88 mm (RAS-24UK)
Pipe insulating material
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
Secure the outdoor unit with the fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
Use Ø8 mm or Ø10 mm anchor bolts and nuts.