– 33 –
8-2. Outdoor Unit (Inverter Assembly)
RAS-M14EAV-E, RAS-M18EAV-E (Heat pump models)
RAS-M14EACV-E, RAS-M18EACV-E (Cooling-only models)
220–240 V ~50Hz
220 V ~60Hz
CONTROL BLOK DIAGRAM (Outdoor unit)
Driver circuit of P.M.V.
Noise
filter
Relay
RY701
Converter
(AC DC)
Input current
sensor
4-way
valve
A unit
P.M.V.
Unit A
send/receive
circuit
Unit B
send/receive
circuit
B unit
P.M.V.
Inverter
(DC AC)
Gate drive
circuit
Gate drive
circuit
Inverter
(DC AC)
Outdoor
fan motor
Compressor
MCC-5015 (SUB P.C.B) MCC-5009 (SUB P.C.B)
Current
detect
Current
detect
M.C.U
Inverter output frequency control
A/D converter function
P.M.V. control
Discharge temp. control
Error displey
Signal communication to MCU
M.C.U
PWM synthesis function
Input current release control
IGBT over-current detect control
Outdoor fan control
High power factor correction control
Signal communication to MCU
Gas side pipe
temp. sensor
(unit B) (TGb)
Gas side pipe
temp. sensor
(unit A) (TGa)
Outdoor Heat-
exchanger temp.
sensor (TE)
Discharge temp.
sensor (TD)
Suction temp.
sensor (TS)
Outdoor air temp.
sensor (TO)
P.M.V : Pulse Motor Valve
PWM : Pules Width Modulation
IGBT : Insulated Gate Bipolar Transistor
*1 : Heat Pump Model Only
High power factor
correction circuit
*1
*1