2. SPECIFICATIONS
The indoor and outdoor units that can be used in combination are shown in the tables below.
Table of models that can be connected
Table of models that can be used in combination
Type Outdoor unit Indoor unit
Heat pump
RAS-M14EAV–E
RAS-B10EKVP–E RAS-B13EKVP–E
RAS-M10UKV–E3 RAS-M13UKV–E3
RAS-M10YDV–E RAS-M13YDV–E
RAS-M18EAV–E
RAS-B10EKVP–E RAS-B13EKVP–E RAS-B16EKVP–E
RAS-M10UKV–E3 RAS-M13UKV–E3 RAS-M16UKV–E3
RAS-M10YDV–E RAS-M13YDV–E RAS-M16YDV–E
Cooling-only
RAS-M14EACV–E
RAS-M10EKCVP–E RAS-M13EKCVP–E
RAS-M10UKCV–E3 RAS-M13UKCV–E3
RAS-M10YDCV–E RAS-M13YDCV–E
RAS-M18EACV–E
RAS-M10EKCVP–E RAS-M13EKCVP–E RAS-M16EKCVP–E
RAS-M10UKCV–E3 RAS-M13UKCV–E3 RAS-M16UKCV–E3
RAS-M10YDCV–E RAS-M13YDCV–E RAS-M16YDCV–E
Type Outdoor unit Combinations of indoor unit models that can be connected
Heat pump
RAS-M14EAV–E 10+10, 10+13
RAS-M18EAV–E 10+10, 10+13, 10+16, 13+13
Cooling-only
RAS-M14EACV–E 10+10, 10+13
RAS-M18EACV–E 10+10, 10+13, 10+16, 13+
13
NOTES
A 1-room connection is not an option for the indoor units (you cannot connect only one indoor unit). A 2-room connection must
always be used for the indoor units (you must connect two indoor units).
With the RAS-M14EAV-E and RAS-M14EACV-E outdoor unit models, the 13 + 13 combination is not an option.
With the RAS-M18EAV-E and RAS-M18EACV-E outdoor unit models, the 13 + 16 or 16 + 16 combination is not an op
tion.
The contents noted in this service manual limit the indoor units to the RAS-B10EKVP-E, RAS-B13EKVP-E, RAS-
B16EKVP-E, RAS-M10EKCVP-E, RAS-M13EKCVP-E and RAS-M16EKCVP-E. For other indoor units that can also be
used in combination, see the service manual of each indoor unit.
SVM-04015
A02-010RAS-M10YDV-E RAS-M10YDCV-E
RAS-M13YDV-E RAS-M13YDCV-E
RAS-M16YDV-E RAS-M16YDCV-E
RAS-M10UKV-E3 RAS-M10UKCV-E3
RAS-M13UKV-E3 RAS-M13UKCV-E3
RAS-M16UKV-E3 RAS-M16UKCV-E3
Indoor Unit
File No.

Table of Contents

Other manuals for Toshiba RAS-B10EKVP-E