EasyManua.ls Logo

Toshiba RAS-B10EKVP-E - Remote Control Indicators

Toshiba RAS-B10EKVP-E
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 7 –
Unit model Indoor RAS-M10EKCVP-E, RAS-M13EKCVP-E, RAS-M16EKCVP-E
Outdoor RAS-M14EACV-E RAS-M18EACV-E
Cooling Capacity (kW) 4.0 5.2
Cooling Capacity range (kW) 1.4 - 4.5 1.4 - 6.2
Heating Capacity (kW)
Heating Capacity range (kW)
––
Power supply 220~240V-1Ph-50Hz / 220V-1Ph-60Hz
Electric
charactaristics
Indoor
(220V/230V/
240V)
Unit model RAS-M10EKCVP-E RAS-M13EKCVP-E RAS-M16EKCVP-E(*1)
Runnning Current (A)
0.15 0.15 0.15
Power Consumption (W) 30 30 30
Power factor (%) 91/87/83 91/87/83 91/87/83
Outdoor
(220V/230V/
240V)
Unit model RAS-M14EACV-E RAS-M18EACV-E
Operation mode Cooling Heating Cooling Heating
Running current (A)
4.87/4.64/4.44 7.12/6.80/6.50
Power Consumption (W) 1020 1540
Power factor (%) 95 98
Starting current (A) 5.17/4.94/4.74 7.42/7.10/6.80
COP(Cooling/Heating) 3.70/– 3.25/–
Operating noise
dB(A)
Indoor
(Cooling/Heat-
ing)
Unit model RAS-M10EKCVP-E RAS-M13EKCVP-E RAS-M16EKCVP-E(*1)
High 42/– 43/– 45/–
Medium 33/– 34/– 36/–
Low 27/– 27/– 29/–
Outdoor
(Cooling/Heat-
ing)
Unit model RAS-M14EACV-E RAS-M18EACV-E
2 indoor units operating
46/– 48/–
Indoor unit Unit model RAS-M10EKCVP-E RAS-M13EKCVP-E RAS-M16EKCVP-E(*1)
Dimension
(mm)
Hight 250 250 250
Width
790 790 790
Depth
215 215 215
Net weight (kg) 9 9 9
Fan motor output (W) 30 30 30
Air fl ow rate (m
3
/h) (Cooling/Heating) 550/– 560/– 640/–
Outdoor unit Unit model RAS-M14EACV-E RAS-M18EACV-E
Dimension
(mm)
Hight 550 550
Width 780 780
Depth 290 290
Net weight (kg) 36 40
Compressor Motor output (W) 750 1100
Type Twin rotary type with DC-inverter variable speed control
Model DA111A1F-20F1 DA130A1F-25F
Fan motor output (W) 43 43
Air fl ow rate (m
3
/h)
1820 2100
Type Flare connection Flare connection
Piping connec-
tion
Indoor unit Unit model RAS-M10EKCVP-E RAS-M13EKCVP-E RAS-M16EKCVP-E (*1)
Liquid side
6.35 6.35 6.35
Gas side
9.52 9.52 12.7
Outdoor unit Unit model RAS-M14EACV-E RAS-M18EACV-E
Liquid side/gas side
6.35 / 9.52 6.35 / 9.52
Maximum length (per unit) (m) 20 20
Maximum length (total) (m) 30 30
Maximum chargeless length(total) (m) 20 20
Maximum height difference (m) 10 10
Additional refrigerant 20g/m (pipe length 21m to 30m) 20g/m (pipe length 21m to 30m)
Name of refrigerant R410A R410A
Weight (kg) 0.90 1.20
Wiring connection Power supply 3 Wires : includes earth
Interconnection 4 Wires : includes earth
Usable temperature range (°C) Indoor
(Cooling/Heating)
21 to 32/0 to 27
Outdoor
(Cooling/Heating)
5 to 43/-10 to 24
Accessory Indoor unit Unit model RAS-M10EKCVP-E RAS-M13EKCVP-E RAS-M16EKCVP-E(*1)
Installation plate 1 1 1
11
Wireless remote controller
1
Batteries 2 2 2
Remote control holder 1 1 1
Zeolite-plus filter 1 1 1
Plasma Pure filter 1 1 1
Remote controller
holder mounting screw
2 (3.1×16L) 2 (3.1×16L) 2 (3.1×16L)
Owner’s manual 1 1 1
Mounting screw
6 (4×25L) 6 (4×25L) 6 (4×25L)
Installation manual 1 1 1
Outdoor unit Unit model RAS-M14EACV-E RAS-M18EACV-E
Installation manual 1 1
Specifications 1 1
0
Drain nipple
0
Water-proof rubber cap 0 0
2-1-2 Specifications
Cooling-only models
(*1) The RAS-M16EKCVP-E cannot be used in combination with the RAS-M14EACV-E.
For performance when each indoor unit is combined with other unit, refer to the separate table.
The specifications may be subject to change without notice for purpose of improvement.

Table of Contents

Other manuals for Toshiba RAS-B10EKVP-E

Related product manuals