Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
 ● Clean the indoor unit and the remote control with a wet cloth when 
needed.
 ● No benzine, thinner, polishing powder or chemically-treated duster.
Air lters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air lters.
3. Vacuum or wash and then dry them.
4. Reinstall the air lters and close the air inlet grille.
MAINTENANCE
22
The unit does not operate.
Cooling or Heating is abnormally low.
 ● The power main switch is 
turned off.
 ● The circuit breaker is 
activated to cut off the power 
supply.
 ● Stoppage of electric current
 ● ON timer is set.
 ● The lters are blocked with dust.
 ● The temperature has been set 
improperly.
 ● The windows or doors are opened.
 ● The air inlet or outlet of the outdoor 
unit is blocked.
 ● The fan speed is too low.
 ● The operation mode is FAN or DRY.
 ● POWER SELECTION function is 
set 75% or 50% (This function is 
depend on remote controller).
TROUBLESHOOTING (CHECK POINT)
23
How to set WEEKLY TIMER
1.  Press 
 to enter WEEKLY TIMER setting.
 
2.  Press   to select desired day in sequence.
  The sequence of day symbol appears on the LCD.
 
 
SU  MO  TU  WE  TH  FR  SA
WEEKLY SUMO
TUWETHFRSA
(All day)
3.  Press   to select the program number.
 ● The program 1 is ready for setting while 
 is 
pressed PG-1 appears on the LCD.
 ● Press 
 to change the program number in 
the sequence program 1 to program 4.
 
PG-1
PG-  2
PG-    3
 
4.  Press    or   to select the desired time.
 ● The time can be set between 0:00 and 23:50 in  
10 minute intervals.
 ● Press and hold the button to change setting time 
for 1 hr.
 ● Only one of ON or OFF timer can be set on each 
program.
 
ON timer display OFF timer display*
* OFF timer is used to stop the air conditioner only. 
The display does not show Operation mode, 
Temperature, Fan speed and others.
5.  Press 
 to select desired operation.
 
6.  Press   or   to select desired temperature.
 ● The temperature can be set between 17°C and 
30°C.
7.  Press 
 to select the desired fan speed.
8.  Add operations, if required.
 ● Press   to use 8°C operation.  
(Notes: Fireplace cannot select and memorize in 
weekly function) 
 ● Press   to use ECO operation.
 ● Press   to use Hi-POWER operation.
 ● Press   to use Silent operation.
WEEKLY TIMER OPERATION
24
Blink
OPERATION AND PERFORMANCE
21
1. Three-minute protection feature: To prevent the unit from being activated 
for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating 
operation starts.
3. Warm air control: When the room temperature reaches the set 
temperature, the fan speed is automatically reduced and the outdoor unit 
will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into 
the room. When the outdoor temperature is too low, use another 
recommended heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit 
where it will not be subjected to snow drifts, accumulation of leaves or 
other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is 
normal because the cracking sound may be caused by expansion/
contraction of plastic.
  Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature Room Temperature
Heating –15°C ~ 24°C Less than 28°C
Cooling –15°C ~ 46°C 21°C ~ 32°C
Dry –15°C ~ 46°C 17°C ~ 32°C
TEMPORARY OPERATION
19
In case of the misplaced or discharged remote control
 ● Pressing the RESET button, the unit can start or 
stop without using the remote control.
 ●  Operation mode is set on AUTOMATIC operation, 
preset temperature is 24°C and fan operation is 
automatic speed.
REMOTE CONTROL A-B SELECTION
20
To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold 
 button on the Remote Control by the tip of the 
pencil. “00” will be shown on the display. (Picture 1)
4. Press 
MODE
 during pushing  . “B” will show on the display and 
“00” will disappear and the air conditioner will turn OFF. The Remote 
Control B is memorized. (Picture 2)
Note: 1. Repeat above step to reset Remote Control to be A.
  2. Remote Control A has not “A” display.
  3. Default setting of Remote Control from factory is A.
1
2