2
1
OTHERS
Gas Leak Test
Check the fl are nut connections for the gas leak with a gas leak detector
or soap water.
Check places for
the indoor unit.
Check places for
the outdoor unit.
Remote Control A-B Selection
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed near.
Remote Control B Setup.
1. Press [RESET] button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on back side of Remote Control.
“00” will be shown on the display (Picture 1).
4. Press [MODE] during pushing [CHECK]. “B” will show on the display
and “00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized (Picture 2).
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not “A” display.
3. Default setting of Remote Control from factory is A.
When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control signal
simultaneously and operate. In this case, the operation can be preserved
by setting either one remote control to B setting. (Both are set to A setting
in factory shipment.)
The remote control signal is not received when the settings of indoor unit
and remote control are different.
There is no relation between A setting/B setting and A room/B room when
connecting the piping and cables.
Test Operation
To switch the TEST RUN (COOL) mode, press [RESET] button for
10 seconds. (The beeper will make a short beep.)
OPERATION /
RESET Button
Auto Restart Function Setting
The product was shipped with Auto Restart function in the OFF position.
Turn it ON as required.
This product is designed so that, after a power failure, it can restart automatically
in the same operating mode as before the power failure.
Information
How to turn ON the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 Beep sound and OPERATION lamp blink 5 time/sec for 5 seconds).
How to turn OFF the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 Beep sound but OPERATION lamp does not blink).
NOTE
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
13