EasyManua.ls Logo

Toshiba RAS-M10U2KCVG-SG1 x5 - Page 50

Toshiba RAS-M10U2KCVG-SG1 x5
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
150 or more
150 or more
1000 or more
150 or
more
300 or more
Side view (Unit: mm)
200 or more
500 or more
500 or more
150 or more
1000 or more
1000 or
more
CAUTION
When the outdoor unit is installed in a place
where the drain water might cause any
problems, Seal the water leakage point tightly
using a silicone adhesive or caulking compound.
When the outdoor unit is to be installed in an elevated
position, be sure to secure its feet.
If the outdoor unit is to be mounted on a wall, make sure
the base plate supporting it is sturdy enough.
The base plate should be designed and manufactured to
maintain its strength over a long period of time, and
sufficient consideration should be given to ensure that the
outdoor unit will not fall.
When the outdoor unit is installed in a place that is always
exposed to strong wind such as a coastal area or on a
high story of a building, secure the normal fan operation
using a duct or a wind shield.
Especially in windy areas, install the unit in such a way as
to prevent the admission of wind.
When the outdoor unit is to be mounted high on a wall,
take particular care to ensure that parts do not fall, and
that the installer is protected.
When doing installation work at ground level, it is usual to
make wiring and pipe connections to the indoor units first,
and then to make connections to the outdoor units.
However, if outdoor work is difficult, you can change the
procedure.
For example, by making adjustments to the wiring and
piping lengths on the inside (rather than the outside).
Precautions for Installation
Necessary Space for Installation
If you need to install the outdoor unit in a location where
there are some obstructions or a wall, secure sufficient
space as shown in the figure below. The cooling effect may
be reduced by 10%.
Upper side view (Unit: mm)
Fixing the Outdoor Unit
Fix the outdoor unit using attachment bolts.
Use 8 mm or 10 mm anchor bolts and nuts.
Do not allow the attachment bolts to protrude by more than
15 mm.
Install the outdoor unit at ground level.
Attach the vibration-proof rubber pads under the fixing legs.
400
150
600
525
150
365
45
Foundation
Support the bottom surface of the
mounting leg that is in contact with
and underneath the bottom plate of
the outdoor unit.
Absorb vibration
with vibration-proof
rubber pads
If only the end
of the
mounting leg
is supported,
it may
deform.
Do not support
the outdoor unit
only with the
mounting leg.
Bottom plate of
outdoor unit
Foundation
GOOD BAD
Foundation
Mounting
leg
15 mm or
less
Drain nipple mounting hole
- 50 -