EasyManua.ls Logo

Toshiba RAS-M10U2KCVG-SG1 x5 - Page 90

Toshiba RAS-M10U2KCVG-SG1 x5
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reactor cover Reactor
relay connector
Reactor cover Reactor
Reactor
Hooks
Partition
plate
Partition plate
No.
7
Part name
Replacement
of reactor
Procedure
1. Reactor to be attached to the inverter
assembly
1) Perform works of Detachment 1 of
1
and
4
.
2) Remove the relay connector of the reactor.
3) Remove the reactor cover.
(Truss head B tight screw Ø4 × 6, 4 pcs.)
4) Remove the reactor. (ST1T Ø4 × 6, 2 pcs.)
5) Mount a new reactor.
2. Reactor to be attached to the partition
plate
1) Perform works of Detachment 1 of
1
and
4
.
2) Remove the reactor from the partition plate.
(ST1T Ø4 × 8, 2 pcs.)
3) Mount a new reactor.
Caution to mount the inverter assembly.
When mounting the inverter assembly to the
partition plate, be sure to attach the hooks
certainly.
Remarks
- 90 -