– 19 –
5. SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAS-M10YKCV-E, RAS-M13YKCV-E, RAS-M16YKCV-E
No. Parts name Type Specifications
1 Fan motor (for indoor) ICF-340-30-2 DC340V, 30W
2 Thermo. sensor (TA-sensor) ( – ) 10kΩ at 25°C
3 DC-DC transformer (T01) SWT-70 DC390V, Secondary DC15V, 12V, 7V
4 Microcomputer ( – )
5
Heat exchanger sensor
( – ) 10kΩ at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-06270 27mH, AC0,64A
7 Diode (DB01) D3SBA60 4A, 600V
8 Capacitor (C03) KMH450VNSN120M25C 120µF, 450V
9 Fuse (F01) FCU250V3.15A T3,15A, 250V
10 Power supply IC (IC01) STR-L472
11 Varistor (R21, R109) 15G561K 560V
12 Resistor (R01) RF-5TK5R6 4,7Ω,5W
13 Louver motor MP24GA Output (Rated) 1W, 16poles, 1phase DC12V
5-2. Outdoor Unit
RAS-3M23YACV-E
No. Parts name Model name Rating
1 SC coil (Noise filter)
SC-15-S06J 15A, 0,6mH
SC-20-01J 20A, 150µH
Primary side DC280V
2 DC-DC transformer SWT-43 Secondary side 7,5V x 1, 13V x 1
26,5V x 3, 16V x 1, 15V x 1
3 Reactor CH38Z-K L=10mH, 16A x 2
4 Outside fan motor ICF-140-40-8 DC140V, 40W
5 Fan control relay AJQ1341
Coil DC12V
Contact AC125V, 3A
6
Discharge temp. sensor
(Inverter attached) 62kΩ (20°C)
(TD sensor)
7
Outside air temp. sensor
(Inverter attached) 10kΩ (25°C)
(TO sensor)
8
Temp. sensor at A room
(Inverter attached) 10kΩ (25°C)
gas side (TGa sensor)
9
Temp. sensor at B room
(Inverter attached) 10kΩ (25°C)
gas side (TGb sensor)
10
Temp. sensor at C room
(Inverter attached) 10kΩ (25°C)
gas side (TGc sensor)
11 Terminal block (9P) ——— 20A, AC250V (9P x 2)
For protection of
3,15A, AC250V
switching power source
12 Fuse
For protection of transistor
15A, AC250V
module breakage
For protection of
25A, AC250V
inverter input overcurrent
13 Electrolytic capacitor
LLQ2G501KHUATF
500µF, DC400V X 4 pieces
400LISN500K35F
14 Transistor module 6MBI25GS-060-01 25A, 600V
15 Compressor DA130A1F-21F 3-phases 4-poles 1100W
16 Compressor thermo. PW-2AL OFF: 125 ± 4°C, ON: 90 ± 5°C
17 Converter module MP7002 Diode: 25A, 600V, IGBT: 40A, 600V
18 Reactor CH43Z-K L = 10mH, 1A x 2