– 27 –
0
Set
temp.
+0,5
+1
+1,5
+2
+2,5
+3
(Set temp.) 25˚C
˚C
M+
*1
*1
*1
L–
(Room temp.) – (Set temp.)
NOTE :
*1: Calculated from difference in motor speed of M+
and L–, and controlled.
Fig. 8-2-1 Auto setting of air flow
8-2. Description of Operation Circuit
Turning [ON] the breaker flashes the operation
lamp.
This is the display of power-ON (or notification of
power failure).
When pushing [START/STOP] button of the
remote control, receive sound is issued from the
main unit, and the next operations are performed
together with opening the vertical air flow louvers.
8-2-1. Fan Only Operation
(The Remote Control MODE Button is
Set to the FAN ONLY Operation)
Once the setting is made, the operation mode is
memorized in the microcomputer so that the
same operation can be effected thereafter simply
by pushing [START/STOP] button.
When the FAN button is set to the AUTO position,
the indoor fan motor operates as shown in Fig. 8-
2-1. When the FAN SPEED button is set to
LOW, MED, or HIGH, the motor operates with a
constant air flow.
ECONO. mode cannot be set.
8-2-2. Cooling Operation
(The Remote Control MODE Button is
Set to the COOL Position)
Once the setting is made, the operation mode is
memorized in the microcomputer so that the
same operation can be effected thereafter simply
by pushing [START/STOP] button.
A cooling operation signal is transmitted to
outdoor unit.
The indoor fan motor operates as shown in Fig.8-
2-2 when FAN button is set to AUTO.
The motor operates with a constant air flow when
the FAN button is set to LOW, MED, or HIGH.
The outdoor unit controls the outdoor fan relay
R01, R02 and R03, and the compressor motor
speed according to the operation command
signal sent from the indoor unit.
Set
temp.
+3
M+
*1
*1
*1
L–
+2,5
+2
+1,5
+1
+0,5
0
–0,5
˚C
(Room temp.) – (Set temp.)
In normal
operation
NOTE :
*1: Calculated from difference in motor speed of M+
and L–, and controlled.
Fig. 8-2-2 Setting of air flow [FAN AUTO]