Appendix — Specifications
CIX40 Power Considerations
162 Strata CIX General Description 12/07
CIX40 Power Considerations
CIX100 Power Considerations
The power supply in each CIX100 Base and Expansion Cabinet furnishes power to all of the
stations and some of the interface peripherals (see
Table 28). The primary AC power for each
cabinet is 120VAC.
BTU Rating
ACTU (1) or BCTU/BEXU (1 installed)
BDKU (5 installed)
RCOU/RCOS (1 installed)
Digital Telephones (40 installed)
CIX100: 105 BTUs (31 watt hours) per cabinet.
CIX670: 190 BTUs (56 watt hours) per cabinet.
Table 27 CIX40 Electrical Characteristics
CIX40 Primary Power
Input AC (Power Supply Specification)
AC frequency
Power
AC input current
105~125VAC
50/60 Hz
CIX40 - 100 watts maximum
1.5A maximum (100 VAC)
Power
Input DC 15V use the factory-shipped AC adapter
Power Converter
DC voltage output specification
-24VDC (-26.3 ~ -28.3VDC)
+5VDC (+4.5 ~ +5.5VDC)
Standard Telephone Ring Circuit (GMAU2 and GSTU1)
Ring Voltage 180V p-p square wave
Ringing capability 1 REN, 1 circuit - one telephone per circuit
Table 28 CIX100 Electrical Characteristics
CIX100 Primary AC Power Voltage
Input AC
AC Frequency
Watts per cabinet (maximum)
120VAC
60 Hz, Single-phase (48Hz~62Hz)
100 watts (maximum)
CIX100 Primary Power Current Consumption (Rating in Amperes)
120VAC
1 cabinet
2 cabinets
1.8 amps
3.6 amps
Power Supply Unit (APSU112A)
DC voltage output specification
-24VDC (-26.3~-27.8VDC, 3.2 DC amps)
+5VDC (+4.5~5.5VDC, 2.0 DC amps)
-5VDC (-4.5~-5.5VDC, 0.2 DC amps)
+3.3VDC (+3.0~3.6VDC, 0.5 DC amps
Table 26 Environmental Characteristics for the CIX670, CIX200, CIX100, and CIX40(continued)