Appendix — Specifications
CIX200 Power Considerations
Strata CIX General Description 12/07 163
CIX200 Power Considerations
CIX670 Power Considerations
The power supply in each CIX670 Base and Expansion Cabinet furnishes power to all of the
stations and some of the interface peripherals (see
Table 30). The primary AC power can be
120VAC, 208VAC or 240VAC. Systems containing six or seven cabinets require 208VAC or
240VAC. See
page 17 for CIX40 requirements.
MAS Power Considerations
Note The MAS is supplied with a standard 15 Amp power cord with a standard three-prong
120VAC that plugs into an AC power outlet. The MAS requires a dedicated, properly
grounded circuit. Customer-supplied commercially available UPS systems should be used
for power failure backup.
Table 29 CIX200 Electrical Characteristics
CIX200 Primary AC Power Voltage
Input AC
AC Frequency
Watts per cabinet (maximum)
120VAC, 4.0 amps max.
Single-phase (45Hz~65Hz)
480 watts (maximum)
Table 30 CIX670 Electrical Characteristics
CIX670 Primary AC Power Voltage
Input AC
AC Frequency
Watts per cabinet (continuous)
Watts for five cabinet system
115±10VAC or 208±20VAC or 240±20VAC
50/60 Hz, Single-phase (48~62Hz)
180
900
CIX670 Primary Power Current Consumption (Rating in Amperes)
Number of Cabinets: 120VAC 208VAC 240VAC
1
2
3
4
5
6
7
3.2 amps
6.4 amps
9.6 amps
12.8 amps
16.0 amps
N/A
N/ A
2.2 amps
4.4 amps
6.6 amps
8.8 amps
11.0 amps
13.2 amps
15.4 amps
2.0 amps
4.0 amps
6.0 amps
8.0 amps
10.0 amps
12.0 amps
14.0 amps
Power Supply Unit (BPSU672)
DC voltage output specification
-24VDC (-26.3~-27.8VDC, 6.0 DC amps)
+5VDC (+4.5~5.5VDC, 4.0 DC amps)
-5VDC (-4.5~-5.5VDC, 0.8 DC amps)
Table 31 MAS Electrical Characteristics
MAS Primary AC Power Voltage
Input AC
AC Frequency
Watts per cabinet (maximum)
120VAC, 5.67 amps max.
Single-phase (50Hz~60Hz)
680 watts (maximum)