Strata CIX Overview
Strata CIX40, CIX100, CIX200, and CIX670 Component Compatibility
4 Strata CIX General Description 12/07
Option Interface Units CIX40 CIX100 CIX200 CIX670
BIOU Option Interface Unit (4-zone paging, relay control & 3-
MOH)
No Yes
Yes
5
Yes
BSIS 4-port Serial Interface Subassembly (installs on processor
card)
Yes Yes Yes Yes
AMDS Remote Maintenance Modem
Yes
(Built-in)
Yes Yes Yes
HPFB-6 Battery Backup Module Yes No No No
ABCS Battery Charger Subassembly No Yes
No
(UPS)
No
LPFU1A - 8-port Power Failure Transfer Unit No No Yes No
Voice Mail CIX40 CIX100 CIX200 CIX670
Stratagy ES Standalone Models Yes Yes Yes Yes
Stratagy iES32 and iES16 No Yes Yes Yes
Stratagy IVP8 No Yes Yes Yes
LVMU1A No Yes Yes Yes
GVPH1A
Yes
1,3
No No No
Maximum Capacities CIX40 CIX100 CIX200 CIX670
KSU Cabinets (base plus expansion) 1 2 2 7
Base Cabinet PCB Slots 4 4 3 8
Expansion Cabinet PCB Slots 0 4 4 10
Total System PCB Slots 4 8 7 68
Trunk/Station/Voice mail Ports 57 112 192 672
Trunk Lines 11 64 96 264
IP Telephones (IPT2000 series)
6
24 72 160 560
Strata Net Channels 24 48 96 264
Digital Telephones 16 72 112 560
Analog Standard Telephones 2 56 58 544
1. DP5022-SDM requires LIC-1-DP5022SDM license to operate on the CIX100/200/670 systems.
2. Release 5.1 hardware is required to support the MIPU and GCOCIH1A on the CIX40.
3. This CIX40 interface is not compatible with the CTX28. Also, GCDU1A and GVMU2A is not compatible with
CIX40.
4. BCOCU1A, BCOCIS1A, RCOU3A, RCOS3A, REMU2A (two-wire/four-wire), RDDU2A and RGLU3A analog
CO line interfaces are required for IP telephone and Strata Net IP applications; older versions do not comply
with VoIP parameters.
5. MDF cross connect wiring only, there is no compatible Extender unit.
6. Refer to Chapter 8 – Telephones and Peripherals for numbers of IPT2000-series phones supported in the
system.
Strata CIX Component Compatibility List (continued)