Strata
®
DK
Technical Bulletin
Toshiba America Information Systems, Inc.
Telecommunication Systems Division
9740 Irvine Blvd., Irvine, CA 92618-1697 (949) 583-3700
http://telecom.toshiba.com
726+,%$
4031068
DK424 to DK424i Upgrade
Procedure Using DKi Admin
This bulletin describes how to upgrade the DK424 to a DK424i system. It also lists the upgrade paths for
various DK424 processors, provides system capacity and line considerations, along with reconfiguration
examples and blank configuration worksheets.
Upgrade Considerations
Upgrade Paths – The following is a list of possible DK424 to DK424i upgrade paths:
♦ RCTU A processors (R1~4.x) >> B1, B2, B3, B5 processors
♦ RCTU B processors (R1~4.x) >> B2, B3, B5 processors
♦ RCTUC/D processors (R1~4.x) >> B3 & B5 processors
♦ RCTU E/F processors (R3~4.x) >> B5 processors
Note For a specific list of all processors, see Page 6 of this bulletin.
System Capacity Verification – Make sure the DK424i system you are upgrading to provides enough
PCB slots, station ports, and CO lines to match the existing DK424 system (see tables below).
DK424i Maximum System Capacities with only Digital T1/PRI Line PCBs
B1CU B2CAU/B2CBU B3CAU/B3CBU B5CAU/B5CBU
1 Cabinet
8 Universal slots
56 Stations Max.
32 T1/PRI lines Max.
64 Stations & Digital lines
2 Cabinets
14 Universal slots
112 Stations Max.
120 T1/PRI lines Max.
128 Stations & Digital lines
3 Cabinets
28 Universal slots
192 Stations Max.
120 T1/PRI lines Max.
248 Stations & Digital lines
5 Cabinets
48 Universal slots
336 Stations Max.
196 T1/PRI lines Max.
432 Stations & Digital lines
DK424i Maximum System Capacities with only Analog Line PCBs
B1CU B2CAU/B2CBU B3CAU/B3CBU B5CAU/B5CBU
TBDK-0042
November 2000