EasyManua.ls Logo

Toshiba Strata DK - Page 2

Toshiba Strata DK
7 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
November 2000 Configuring DK424i Cabinets with DK424 PCBs
DK424 to DK424i Upgrade Procedure Using DKi Admin
2 of 7
Configuring DK424i Cabinets with DK424 PCBs
RCTU, R1~R3 Software with Tie and/or DID Lines
When installing PCBs in the DK424i cabinets, all PCBs must be installed in the same order in relation
to each other as they were in the DK424 cabinets. You may have to skip slots in the new cabinets to
place RDTU PCBs into the allowed slots.
Only install the PCBs that currently exist in the DK424 cabinets into the DK424i cabinets do not add
more line or station PCBs during the upgrade. The only exception to this rule is that you can add an
RSIU, PIOU, PIOUS, RSSU.
RCTU, R1~R3 Software Without Tie/DID, or any R4.x Software With or
Without Tie/DID Lines
Only install the PCBs that currently exist in the DK424 cabinets into the DK424i cabinets do not add
more line or station PCBs during the upgrade. The only exception to this rule is that you can add an
RSIU, PIOU, PIOUS, RSSU.
When installing PCBs in the DK424i cabinets, all station PCBs and the RATU must be installed in the
same order in relation to other station PCBs as they were in the DK424 cabinets.
When installing PCBs in the DK424i cabinets, all CO line PCBs must be installed in the same order in
relation to other CO line PCBs as they were in the DK424 cabinets.
When moving station PCBs from DK424 to DK424i cabinets, you do not have to installed them in the
same order in relation to CO line PCBs, and vice-versa .
Do not skip slots except when necessary for RDTU, RPTU, and RWIU. Make sure these PCBs are
installed in the correct cabinet slot per Worksheet 6 of the
Strata DK I&M Manual, Chapter 6
DK424i Configuration.
PIOU, PIOUS, RSSU, etc., can be installed in any DK424i slot that does not conflict with RDTU,
RPTU or RWIU vacant slots. These PCBs do not have to be installed in any order corresponding to
where they were installed in DK424 cabinets. The RSIU must be installed in slot S101.
1 Cabinet
8 Universal slots
56 Stations Max.
32 CO lines Max.
64 Stations & Analog lines
2 Cabinets
14 Universal slots
104 Stations Max.
120 CO lines Max.
112 Stations & Analog lines
3 Cabinets
28 Universal slots
192 Stations Max.
120 CO lines Max.
248 Stations & Analog lines
5 Cabinets
48 Universal slots
336 Stations Max.
200 CO lines Max.
376 Stations & Analog lines

Other manuals for Toshiba Strata DK

Related product manuals