November 2000 Configuring DK424i Cabinets with DK424 PCBs
DK424 to DK424i Upgrade Procedure Using DKi Admin
P
re
l
i
m
i
n
a
ry
a
n
d
Co
n
f
i
d
e
n
t
i
a
l
3 of 7
Reconfiguration Example: The following tables show two examples of how to load DK424i cabinet slots from
the same DK424, RCTU E/F R4, system.
T=Telephone type PCB
L=CO Line type PCB
Existing DK424 Cabinets Example 1, DK424i Cabinets Example 2, DK424i Cabinets
Slot PCB T/L No. Slot PCB T/L No. Slot PCB T/L No.
R11 RCTUE B101 B5CAU B101 B5CAU
RCTU RCTUF B102 B5CBU B102 B5CBU
S11 RSIU S101 RSIU S101 RSIU
S12 PDKU T1 S102 PDKU T1 S102 PDKU T1
S13 RSTU T2 S103 RDTU L1 S103 RSTU T2
S14 PEKU T3 S104 VACANT L1 S104 PEKU T3
S15 RDTU L1 S105 RCOU L2 S105 RDTU L1
S16 VACANT L1 S106 RSTU T2 S106 VACANT L1
S21 RCOU L2 S107 RPTU L3 S107 RCOU L2
S22 PEKU T4 S108 VACANT L3 S108 PEKU T4
S23 RPTU L3 S201 PEKU T3 S201 PDKU T5
S24 VACANT L3 S202 PEKU T4 S202 PDKU T6
S25 PDKU T5 S203 RCOU L4 S203 RPTU L3
S26 PDKU T6 S204 RCOU L5 S204 VACANT L3
S27 RCOU L4 S205 REMU L6 S205 RCOU L4
S28 RCOU L5 S206 PDKU T5 S206 PDKU T7
S31 REMU L6 S207 PDKU T6 S207 RCOU L5
S32 PDKU T7 S208 PDKU T7 S208 RSTU T8
S33 RSTU T8 S209 RSTU T8 S209 PEK T9
S34 PEKU T9 S210 PEKU T9 S210 PDKU T10
S35 PDKU T10 S301 RDTU L7 S301 RDSU T11
S36 RDSU T11 S302 VACANT S302 REMU L6
S37 PDKU T12 S303 PDKU T10 S303 RDTU L7
S38 PDKU T13 S304 RDSU T11 S304 VACANT L7
S41 RDTU L7 S305 PDKU T12 S305 PDKU T12
S42 VACANT L7 S306 PDKU T13 S306 PDKU T13
S43 PDKU T14 S307 PDKU T14 S307 PDKU T14
S44 RDDU L8 S308 PESU T15 S308 RDDU L8
S45 PESU T15 S309 PDKU T16 S309 RESU T15
S46 PDKU T16 S310 RDDU L8 S310 RCOU L9
S47 RSTU T17 S401 RCOU L9 S401 PDKU T16
S48 RCOU L9 S402 RSTU T17 S402 RSTU T17
S51 PDKU T18 S403 PDKU T18 S403 PDKU T18
S52 S404 S404
S53 S405 S405