English - 25 -
RS232 HEX COMMANDS
Protocol Test Steps
RJ12 and DSUB9 both are connected to UART 0. UART 1 is connected to the OPS module for sending
OPS to monitor commands. UART 1 is not reachable via the external RS232 or LAN port.
a. Enter Signage Settings Menu.
b. Change ASCII option to HEX in UART 0 or UART 1 sub-menu item
c. Where UART0 is the external RS232 port and UART1 is the OPS UART.

Baud Rate :
Parity : None
Data Bits : 8
Stop Bits : 1
Handshake : None

Note: If command sent is successful, a ACK reply of 06 will be received.
Error Responses
NAK reply: 15 

Error reply: 1C 00 00
