Do you have a question about the Toshiba TMC7 Series and is the answer not in the manual?
Manufacturer | Toshiba |
---|---|
Type | Programmable Logic Controller (PLC) |
Communication Ports | RS-232, RS-485 |
Programming Language | Ladder Diagram |
Operating Temperature | 0 to 55°C |
Power Supply | 100-240 VAC |
Warning about dangerous voltages and proper installation by qualified electricians.
User's responsibility for proper grounding and branch circuit protection according to codes.
TMC7 is not short circuit proof; requires full testing after overload or short circuit.
TMC7 has an internal bypass for SCRs during run, allowing installation in non-ventilated enclosures.
Lists starting, stopping, protection, and interface features of the TMC7 soft starters.
Explains the structure of TMC7 part numbers, including control supply voltage and kW rating.
Details current ratings for various TMC7 models at different temperatures and utilization categories.
Provides physical dimensions and weights for different TMC7 model series.
Shows mounting recommendations and derating information for TMC7 soft starters.
Lists suitable Bussman & Ferraz semiconductor fuses for Type 2 coordination with TMC7.
Details wire sizes, torque specifications, and conductor types for power terminations.
Covers mains supply, control supply, control inputs, relay outputs, and environmental specifications.
Details EMC emission standards and class for the TMC7 soft starter.
Lists EMC immunity test levels for electrostatic discharge, RF fields, and transients.
Specifies rated short-circuit currents for different TMC7 models.
Provides heat dissipation values during start and run phases.
Lists relevant standards approvals (IEC 60947-4-2) for the TMC7.
TMC7 soft starters provide current limit soft start, soft stop, and motor protection functions.
Shows electrical schematics for TMC7 installation with a shunt trip device and with a line contactor.
Details the two control voltage configurations available for the TMC7 Series.
Illustrates control circuits for 2-wire and 3-wire control with different voltage configurations.
Explains how to connect motor thermistors to TMC7 terminals C1 & C2.
Identifies nine adjustable parameters on the TMC7, including FLC, ramp, limit, and trip class.
Explains the LED status indicators (Ready, Run) and their meanings.
Lists diagnostic trip codes indicated by Ready LED flashes and their descriptions.
Lists optional accessories for the TMC7 Series, including remote operator and communication modules.
Describes the TMC7 Remote Operator, its functionality, and installation.
Details the MODBUS Module for control and monitoring via a MODBUS RTU network, including adjustment and register mapping.
Describes the Profibus Module for control and monitoring via a Profibus network, including address and data structure.
Explains the DeviceNet Module for control and monitoring via a DeviceNet network, including adjustment and data transmission.
Mentions the AS-i Module for control and monitoring via an AS-i network, noted as under development.
Describes the PC Set-up Software for managing multiple soft starters and its system requirements.