Advanced Setup
Page 14
Continued
Select INTELLIMIST (ON)
MICROPULSE Control,
or conventional humidity
control (OFF).
Adjust the MicroPulse
interval for the size
HVAC equipment by
Tonnage.
Select ON for ‘Standalone’
Humidity/Fan operation.
Inteillistat will turn on
the fan and humidifier
with a humidity demand,
or, Select OFF to only
turn on the humidifier
if in Heat or Fan and there
is a humidity demand.
I0
I I
Setup
Setup
Ton
7
8
9
Setup
Pls
3
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Adjust the minimum
difference between
cooling & heating
setpoints.
(0 - 6 )
Setup
2
81f
Select the cycles per
hour limit.
d=cycles per hour
limit defeated.
d1=d + defeat 5 min.
Compressor lockout.
(d, d1, 2 - 6)
cy
Setup
6
ON
ON
Humidity
(1 - 7)
On
On
Off
Off
Step 10 only appears if Step 9 is On
Heat
Cool