About Advanced Features & Operation
Page 19
MULTI-STAGE OPERATION - Control up to 2 Heat, 1 Cool Stages.
The 2nd Stage of heat is
(A) the 1st Stage has been on a minimum of 2 minutes and
(B) the temperature spread
greater than: the setpoint
turned on when:
from the setpoint is equal to or
plus the deadband, plus
2 degrees.
WINDOW CONDENSATION CONTROL - When used with both an
INTELLIMIST humidifier and an outdoor sensor, the INTELLISTAT
control will reduced the moisture put into the airflow when it
is cold outdoors. This will reduce the moisture buildup on the
inside of windows.
The amount of reduction in humidity is calculated with a
complex formula using various parameters which include:
indoor temperature and outdoor temperature.
To activate this feature, Select ON, Step # 12 in the
Advanced Setup section.
Heat
Setpoint
Cool
Setpoint
Dead
Band
Dead
Band
2 degrees
1st Stage
turn on
2nd Stage
turn on
1st Stage
turn on
Heating
Cooling