1-39
TROUBLESHOOTING
This page contains troubleshooting advice for the mechanical system of the travel and load handling control device.
In the case of an error code being recieved, or trouble with the electrical system, refer to the troubleshooting section.
● Idle switch open error
Check the injection pump
Checking the components
of the travel and load
handling control device
A defect in the mechanical system of the travel and
load handling control device
.
Check the components of the travel and load
handling control device.
Not broken
Check that the injection pump return spring is
not broken.
Broken
Replace the return spring
Remove the interference.
There is
interference
Move the link by hand, and check that there is
no interference with surrounding parts.
There is no interference
Mechanically no cause can be found, therefore
refer to the travel and load handling control device
electrical system troubleshooting.
Retighten the installation bolts.
There is
looseness or
rattling
Check that there is no looseness or rattling in the
motor bracket.
There is no looseness
or rattling
Replace defective components.
There is
bending
Check that there is no bending in the connecting
rod or bracket.
There is no bending
Clean and grease the joint section.
There is
catching
Check that there is no catching on the sliding
portion of the ball joint.
There is no catching
Outside the range of the motor operation warranty.
90°C (194°F )
or more
Check that the temperature around the motor in
use is 90°C (194°F) or less.
90°C (194°F) or less