Short Guide TU501-x v4.2, May 2019, ©Trackunit 2019 8
Input filtering (INFILT)
In case the main breaker is on the negative
wire (ground wire from the machine battery),
the inputs may register a voltage level and
start counting operating hours.
To avoid this situation, the digital input 4
(pink wire) should be connected to the
chassis/ground on the machine.
The infilt function should be activated via
“Verify my Trackunit”
Activation of input filtering
Go to: http://verify.trackunit.com/
NB! Enabling the filtering function will
disable inputs 1 to 3 when input 4 is
on/active. This can prevent all digital input
alarms. It will also disable the use of any
alarm function on digital input 4.