Digit 22— Electrical Connections
F = Able to Flip for LH/RH Connections (VCEF
Only)
L = Left, Airflow hits in face
R = Right, Airflow hits in face
0 = Opposite side connection, coil and control
(VCWF Only)
Note: VCCF/VCWF can be flipped in field for
opposite connections.
Digit 23— Transformer
0 = None
1 = 120/24V, 50 VA
2 = 208/24V, 50 VA
3 = 240/24V, 50 VA
4 = 277/24V, 50 VA
5 = 480/24V, 50 VA
6 = 347/24V, 50 VA
7 = 380/24V, 50 VA
8 = 575/24V, 50 VA
Note: For VCEF units with transformers the
VA depends on the staging, control,
and contactor type (ranges are 50 VA
or 75 VA)
Digit 24 Disconnect Switch
0 = None
W = With
Note: VCCF/VCWF— toggle disconnect.
VCEF-door interlocking power
disconnect.
Digit 25 Power Fuse
0 = None
W = With
Digit 26 Electric Heat Voltage
0 = None
A = 208/60/1
B = 208/60/3
C = 240/60/1
D = 277/60/1
E = 480/60/1
F = 480/60/3
G = 347/60/1
H = 575/60/3
J = 380/50/3
K = 120/60/1
Digit 27, 28, 29 Electric Heat kW
000 = None
010 = 1.0 kW
015 = 1.5 kW
460 = 46.0 kW
Notes:
0.5 to 8.0 kW in 1/2 kW
increments
8.0 to 18.0 kW in 1 kW
increments
18.0 to 46.0 kW in 2 kW
increments
Digit 30 Electric Heat Stages
0 = None
1 = 1 Stage
2 = 2 Stages Equal
3 = 3 Stages Equal
Digit 31 Electric Heat Contactors
0 = None
1 = 24V Magnetic
5 = 0–10Vdc SCR Heat; UC400/UC210
6 = 0–10Vdc SCR Heat; FMTD/ENCL/DD00
7 = 24V SSR (Solid State Relay)
Digit 32, 33— Not Used
00 = Not Applicable
Digit 34 Actuator
0 = Standard
A = Spring Return, Normally Open
B = Spring Return, Normally Closed
C = Belimo Actuator
G = Trane Analog Actuator (UC210 or UC400
only)
Digit 35 Sensor Options
0 = Standard, Wired
3 = Trane Air-Fi® Wireless Communications
Interface
Digit 36 Pre-wired Factory
Solutions
0 = None
1 = Factory-mounted DTS
2 = HW Valve Harness
3 = Both DTS/HW Valve Harness
4 = Averaging DTS Factory-installed in Unit
(Required UC210/UC400 w/SCR Heat)
5 = Analog HW Valve, field provided
6 = Factory-mounted DTS and HWV Harness
Digit 37 Integral Attenuator with
Cam Lock Bottom Access
0 = None
1 = Attenuator and bottom access - left side
controls
2 = Attenuator and bottom access - right side
controls
3 =Attenuator and bottom access - left side
controls, right side water coil connections
4 = Attenuator and bottom access - right side
controls, left side water coil connections
Digit 38 —Piping Package
0 = None
A = 2–Way Automatic Balancing
B = 3–Way Automatic Balancing
C = 2-Way Standard Valve Only, Floating
Point Actuator
D = 3-Way Standard Valve Only, Floating
Point Actuator
E = 2-Way Standard Valve Piping Package,
Floating Point Actuator
F = 3-Way Standard Valve Piping Package,
Floating Point Actuator
G = 2-Way Belimo Valve Only, Floating Point
Actuator
H = 3-Way Belimo Valve Only, Floating Point
Actuator
J = 2-Way Belimo Valve Piping Package,
Floating Point Actuator
K = 3-Way Belimo Valve Piping Package,
Floating Point Actuator
L = 2-Way Belimo Valve Only, Analog
Actuator
M = 3-Way Belimo Valve Only, Analog
Actuator
N = 2-Way Belimo Valve Piping Package,
Analog Actuator
P = 3-Way Belimo Valve Piping Package,
Analog Actuator
Digit 39 Water Valve
0 = None
1 = Trane HW Valve 0.7 Cv
2 = Trane HW Valve 2.7 Cv
5 = Analog HW Valve, field provided (UC210
or UC400 only)
6 = Trane HW Valve, 1.7 Cv
7 = Trane HW Valve, 5.0 Cv
A = Belimo HW Valve, 0.3 Cv
B = Belimo HW Valve, 0.46 Cv
C = Belimo HW Valve, 0.8 Cv
D = Belimo HW Valve, 1.2 Cv
E = Belimo HW Valve, 1.9 Cv
F = Belimo HW Valve, 3.0 Cv
G = Belimo HW Valve, 4.7 Cv