FIGURE 20- USER INTERFACE MENU- 24V MODE
Installer's Guide
CMFRT CNT MODE
24VAC [24VAC] COMM
24V Mode
Setup Menu
COOLING CFM
CFM PER TON
CLG STAGES
CLG 1ST STG CFM
CONTFAN CFM
FAN PRERUN DLY
FAN SHRTRUN DLY
FAN OFF DELAY
$3_, I_
HEAT CFM
FACTORY DEFLTS
I EXIT
[ ] denotes the current setting
m=minutes
Setup Options
COOLING CFM
CFM PER TON
400 [400] 430 450 290 310 330 350 370
CLG STAGES
STG1 [STG1] STG 2
CLG 1ST STG CFM
CONT FAN CFM
50% [50%] 75% 100% 25%
FAN PRERUN DLY
NONE [NONE] lm50%
FAN SHRTRUN DLY
NONE [NONE] 4m80% 7Y=m80%
FAN OFF DLY
1½m100% [1½m100%] NONE lm50% 2m50% 3m50%
HEAT CFM
FACTORY DEFLTS
NO [NO] YES
EXIT
NO [NO] YES
_3_ CLG 1ST STG CFM menu will not appear if STG1 is selected in CLG stages menu.
* unit specific
Model COOLING CFM options
31 3T [3T] 1½T 2T 2½T
37 3T [3-r] 2T 2½T
40 3½T [3½-r] 2T 2½T 3T
49 4T [4T] 5T 3T 3½T
65 5T [5T] 3T 3½T 4T
unit specific
Model CLG 1ST STG CFM options
31 50% [50%] 55% 65% 80%
37 50% [50%] 55% 65% 80%
40 55% [55%] 65% 80% 50%
49 55% [55%] 65% 80% 50%
65 60% [60%] 65% 80% 50%
_* unit specific
Model
31
37
40
49
65
HEAT CFM options
1130 [1130] 1350 700 1000
1100 [1100] 1450 600 900
1100 [1100] 1400 600 900
1400 [1400] 1700 800 1100
1500 [1500] 1800 900 1200
IPRINTED FROM D802236P01 REV2 I
18-GE11 D1-4 13