CG-SVX027D-GB
34
4 UNT-PRC002-GB
Technical Data
FWD 08 12 20 30 45
Power supply (V/Ph/Hz) 230/1/50
Capacities
Cooling capacity on water (1) (kW) 5,2 8,3 15 18,8 30,1
Heating capacity on water (2) (kW) 6,3 11,9 18,9 20,9 38,2
Fan motor (type) 2 x direct drive centrifugal
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
Current amps (3) (A) 1,1 2,2 3,1 4,7 5,5
Start-up amps (A) 3,2 5,5 9,3 14,1 16,5
Air flow
minimum (m
3
/h) 490 980 1400 1800 2700
nominal (m
3
/h) 820 1650 2300 3000 4500
maximum (m
3
/h) 980 1970 2600 3600 5400
Main coil
Water entering/leaving connections (type) ISO R7 rotating female
(Dia) 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
Electric heater (accessory for blower only)
Electric power supply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacity (kW) 2/4 8 10 12 12
Hot water coil (accessory for blower only)
Heating capacity (4) (kW) 6,3 12 17,4 22,4 34,5
G2 filter (filter box accessory)
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 filter (filter box accessory)
Quantity - 2 2 2 2
Dimensions ( LxWxth) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
Condensate pump (accessory) (type) Centrifugal
Water flow - lift height (l/h - mm) 24 - 500
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions
Width x Depth (mm) 890 x 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour galvanised steel
Recommended fuse size
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Communication Interface Options
Percent capacity output
The controller provides an analog voltage output
(0-10 VDC) to communicate active unit capacity [%].
This signal is available on option module 1A4, Terminal
block J2 – Y1, identified on the wiring diagram as S1.
General
WARNING Ground wire! All field-installed wiring must
be complete by qualified personnel, and comply with
the local codes and regulations. Failure to follow this
instruction could resut in death or serious injury.
Field wiring for the communication link must meet the
following requirements:
All wiring must be in accordance with local codes and
regulations.
Communication link wiring must be shielded, twisted
pair wiring (Belden 8760 or equivalent), below table
provides recommendation for wire size selection:
The communication link cannot pass between
buildings
All units on the communication link can be connected
in a “daisy chain” configuration.
Note: to prevent control malfunctions, do not run low
voltage wiring (< 30 V) in conduit with conductors
carrying more than 30 V.
Table 5 - Wire Size
Ø
Wire Size Maximum Length
of Communication Wire
2.5 mm² 1525 m
1.5 mm² 610 m
1.0 mm² 305 m
Communication wiring
A
B C D
A = LonTalk communication
B = BACnet communication
C = ModBus Communication
D = pCOWeb Communication
LonTalk Communication
Unit chiller controller provides integrated LonTalk
communication between chiller and the Building
Automation System (BAS). The input/outputs include
both mandatory and optional network variables
as established by the LonMark Functional Chiller
Profile 8040.
Installation Recommendations
The Lon interface uses an Echelon FTT-10 transceiver,
which is approved to be used on the TP/FT-10 channel.
This channel is characterized by the following main
features:
It consists of up to 60 nodes on a single network
segment
Data rate : 78 125 kbps
Maximum distance : 1400 meters
Recommended topology : daisy chain with double end
terminator (105 ohms)
For futher details, refer to the official documentation
LonWorks® FTT-10A free topology transeiver users
guide and to the official LonWorks® guidelines
LonMark® layer 1-6 interoperability guidelines
version 3.0.
These documents and additional information are
available on the internet site www.lonmark.org
BACnet Communication
Unit chiller controller provides integrated BACnet
communication between chiller and the Building
Automation System (BAS).
ModBus Communication
Unit chiller controller provides integrated ModBus
communication between chiller and the Building
Automation System (BAS).
pCOWeb Communication
Unit chiller controller provides integrated pCOWeb
communication between chiller and the Building
Automation System (BAS).