Trane EXHF 006-070 - GEH;GEV Model Number Decoding (.5 to 25 Tons)

Trane EXHF 006-070
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WSHP-SVX01Q-EN 5
Digits 1-3 - Unit Configuration
GEH = Standard Efficiency Horizontal
.5 to 15Tons
GEV = Standard Efficiency Vertical
.5 to 25Tons
Digit4-Development Sequence
E = R-410A
Digits 5-7 - Nominal Capacity
006 = .5Tons
009 = .75Tons
012 = 1Tons
015 = 1.25Tons
018 = 1.5Tons
024 = 2Tons
030 = 2.5Tons
035 = 3Tons (Horizontal only)
036 = 3Tons (Vertical only)
042 = 3.5Tons
048 = 4Tons
060 = 5Tons
072 = 6Tons
090 = 7.5Tons
120 = 10Tons
150 = 12.5Tons
180 = 15Tons
240 = 20Tons
300 = 25Tons
Digit 8 - Voltage (Volts/Hz/Phase)
0 = 115/60/1
1
1 = 208/60/1
2 = 230/60/1
3 = 208/60/3
4 = 460/60/3
5 = 575/60/3
7 = 265/60/1
8 = 230/60/3
Digit 9 - Heat Exchanger
1 = Copper-Water Coil
2 = Cupro-Nickel Water Coil
7 = Insulated Copper-Water Coil
8 = Insulated Cupro-Nickel Water Coil
Digit 10 - Current Design
Sequence
Digit 11 - Refrigeration Circuit
0 = Heating and Cooling Circuit
2 = Heating and Cooling Circuit with
Hot Gas Reheat
3 = Heating and Cooling Circuit with
Waterside Economizer
4 = Heating and Cooling Circuit with HGR
and WSE
2
1
.5 to 1Ton only
2
6 to 25 Tons only
Digit 12 - Blower Configuration
1 = Standard Blower Motor
3
2 = High Static Blower Motor
3
A = Drive Package A
B = Drive Package B
C = Drive Package C
D = Drive Package D
E = Drive Package E
F = Drive Package F
G = Drive Package G
H = Drive Package H
J = Drive Package J
1*= 2 Speed Drive Package A
2*= 2 Speed Drive Package B
3 = 2 Speed Drive Package C
4= 2 Speed Drive Package D
5= 2 Speed Drive Package E
6= 2 Speed Drive Package F
7= 2 Speed Drive Package G
8= 2 Speed Drive Package H
9= 2 Speed Drive Package J
Digit 13 - Freeze Protection
A= 20°F Freezestat
4
B= 35°F Freezestat
Digit 14 - Open Digit = 0
Digit 15 - Supply-Air
Arrangement
B = Back Supply-Air Arrangement
F = Front Supply-Air Arrangement
L = Left Supply-Air Arrangement
R = Right Supply-Air Arrangement
T = Top Supply-Air Arrangement
Digit 16 - Return-Air
Arrangement
B = Back Return-Air Arrangement
2
F = Front Return-Air Arrangement
2
L = Left Return-Air Arrangement
R = Right Return-Air Arrangement
Digit 17 - Control Types
0 = Basic 24V Controls
5
D = Deluxe 24V Controls
B =Tracer® ZN524 Controls
F = UC400
G = UC400 w/Wireless Comm
Digit 18 - Tstat/Sensor Location
0 = Wall Mounted Location
Digit 19 - Fault Sensors
1 = Condensate Overflow Sensor
3 = Condensate Overflow and Filter
MaintenanceTimer
6 = Condensate Overflow and Fan Status
J = Fan Status, Filter MaintenanceTimer
and Condensate Overflow Sensor
3
.5 to 5 Tons only
4
Extended Range Geothermal
5
.5 to 5 Tons only
Digit 20 - Temperature Sensor
0 = NoTemperature Sensor
1 = Entering Water Sensor
Digit 21 - Open
Digit 22 - Electric Heat
0 = No Electric Heat
1 = Internal Boilerless Electric Heat
3
4 = External Boilerless Electric Heat
5 = External Supplemental Electric Heat
2
Digit 23 - Open
Digit 24 - Filter Type
1 = 1"Throwaway Filter
2 = 2"Throwaway Filter
4=2”MERV8
5=2”MERV13
Digit 25 - Acoustic Arrangement
0 = Enhanced Sound Attenuation
1 = Deluxe Sound Attenuation
6
Digits 26-36 - Does Not Apply to
GEH or GEV
00000000000 = Digits 26-36 are not
applicable to the GEH or GEV products
6
.5 to 5 Tons (horizontal only)
Model Number Description - .5 to 25 Tons