Start-Up
92 WSHP-SVX01Q-EN
GEH*030 (60 Hz)
GEH*024 (50 Hz)
86 5.6 126-146 310-395 11-14 20-26 168-193 365-465 11-14 38-49
GEH*030 (60 Hz)
GEH*024 (50 Hz)
86 7.0 126-145 302-384 9-11 20-26 174-200 370-470 9-11 39-50
GEH*030 (60 Hz)
GEH*024 (50 Hz)
95 5.6 128-148 350-446 11-14 19-25
GEH*030 (60 Hz)
GEH*024 (50 Hz)
95 7.0 128-147 341-434 9-11 19-25
GEV*030 (60 Hz)
GEV*024 (50 Hz)
35 76-88 266-338 6-7 21-30
GEV*030 (60 Hz)
GEV*024 (50 Hz)
35 78-90 268-341 5-6 22-31
GEV*030 (60 Hz)
GEV*024 (50 Hz)
45 5.6 115-132 172-218 12-15 21-27 87-100 275-351 6-8 24-33
GEV*030 (60 Hz)
GEV*024 (50 Hz)
45 7.0 115-132 165-210 9-12 21-27 90-103 278-354 5-7 24-34
GEV*030 (60 Hz)
GEV*024 (50 Hz)
55 5.6 116-134 201-256 12-15 20-26 104-119 292-371 8-10 27-37
GEV*030 (60 Hz)
GEV*024 (50 Hz)
55 7.0 116-134 194-247 9-12 21-26 107-123 295-375 6-8 28-38
GEV*030 (60 Hz)
GEV*024 (50 Hz)
68 5.6 121-139 242-308 11-15 20-26 122-141 311-396 9-11 31-41
GEV*030 (60 Hz)
GEV*024 (50 Hz)
68 7.0 120-138 234-298 9-12 20-26 126-145 314-400 7-9 32-42
GEV*030 (60 Hz)
GEV*024 (50 Hz)
75 5.6 122-140 268-341 11-14 20-26 136-157 324-412 9-12 34-44
GEV*030 (60 Hz)
GEV*024 (50 Hz)
75 7.0 122-140 260-331 9-12 20-26 141-162 328-418 8-10 34-45
GEV*030 (60 Hz)
GEV*024 (50 Hz)
86 5.6 124-142 311-396 11-14 19-25 161-185 345-439 11-14 38-49
GEV*030 (60 Hz)
GEV*024 (50 Hz)
86 7.0 123-142 303-385 9-11 19-25 167-192 350-445 9-11 39-50
GEV*030 (60 Hz)
GEV*024 (50 Hz)
95 5.6 125-144 351-447 11-14 19-25
GEV*030 (60 Hz)
GEV*024 (50 Hz)
95 7.0 125-144 342-436 9-11 19-25
GEHE035 (60 Hz) 32 8.4 87-100 267-340 4-5 18-27
GEHE035 (60 Hz) 45 6.6 134-155 180-229 12-15 20-26 103-118 282-359 6-8 22-31
GEHE035 (60 Hz) 45 8.4 134-154 174-222 9-12 20-26 106-121 285-362 5-6 22-32
GEHE035 (60 Hz) 55 6.6 136-156 208-265 12-15 20-25 119-136 297-377 7-9 25-35
GEHE035 (60 Hz) 55 8.4 136-156 201-256 9-12 20-26 122-140 300-382 6-8 25-35
GEHE035 (60 Hz) 68 6.6 138-159 250-318 12-15 19-25 142-163 318-405 9-11 29-39
GEHE035 (60 Hz) 68 8.4 138-158 242-308 9-12 19-25 146-168 323-411 7-9 30-40
GEHE035 (60 Hz) 75 6.6 139-160 275-350 12-15 18-24 155-179 331-422 10-12 32-42
GEHE035 (60 Hz) 75 8.4 139-160 266-339 9-11 18-24 161-185 336-428 8-10 33-43
GEHE035 (60 Hz) 86 6.6 142-163 317-404 11-14 18-24 179-206 354-450 11-14 36-47
GEHE035 (60 Hz) 86 8.4 142-163 309-393 9-11 18-24 185-213 359-457 9-11 37-49
GEHE035 (60 Hz) 95 6.6 144-166 355-452 11-14 17-23
Table 53. Operating pressures in cooling/heating for GE* units (continued)
Operating Data
Model No.
Entering
Water
Temp
(°F)
Water
Flow
(GPM)
Cooling Heating
Suction
Pressure
(psig)
Discharge
Pressure
(psig)
Water
Temp
Rise
(°F)
Air Temp
Drop
(°F DB)
Suction
Pressure
(psig)
Discharge
Pressure
(psig)
Water
Temp
Drop
(°F)
Air
Temp
Rise
(°F DB)