Product Type | Thermostat |
---|---|
Brand | Trane |
Model | TZEMT400BB32MAA |
Compatibility | Compatible with most HVAC systems |
Programmable | Yes |
Humidity Control | No |
Energy Star Certified | No |
Connectivity | Z-Wave |
Display | LCD |
Power Source | 24V AC |
Remote Access | Yes, via Schlage LiNK system |
Voltage hazard. Can cause electrical shock or equipment damage. Disconnect power before installation.
Remove the existing thermostat cover from the wall plate, leaving wires attached. Consult original instructions if needed.
Check if your system requires a 24 VAC common wire, skipping if it's a heat pump or already has a C wire.
Connect a 24 VAC common wire to power the thermostat, typically using a blue wire.
Label wires on the existing thermostat to match terminal names, not colors. Note special cases.
Remove the existing wall plate, ensuring wires do not pull back into the wall. Note mercury notice.
Determine system type (Gas, Electric, Heat Pump, Single/Multi-Stage) by checking wire labels.
Separate the new thermostat face from the wall plate by applying pressure at the top tabs.
Mark, drill, and prepare mounting holes for the new wall plate, ensuring level placement.
Pull wires through the wall plate hole and attach the wall plate to the wall using two screws.
Consult wiring tables for Gas/Electric or Heat Pump systems to match existing thermostat terminals to new ones.
Securely attach wires to the correct terminals on the new thermostat, ensuring bare wires don't touch.
Cut the internal JP1 jumper wire if wires are connected to both 24RC and 24RH terminals.
Tuck wires flat, align the thermostat face with the wall plate, and press firmly to secure.
Turn power back on to the heating and cooling system. Check thermostat display for initial information.
Set the current time and date on the thermostat via the System Settings menu.
Follow prompts to select the correct system type (Gas Furnace, Electric Furnace, Heat Pump) for proper operation.
Configure settings for Gas Furnace Multistage systems, including 2nd Stage Heat and Cool.
Configure settings for Electric Furnace systems, including Fan Type and 2nd Stage Heat/Cool.
Configure settings for Heat Pump systems, including System Type, Fan Type, C/O Type, and 2nd Stage Heat/Cool.
Test fan operation by setting the fan to ON and then AUTO, verifying air movement.
Test cooling by setting mode to COOLING and lowering setpoint below room temperature.
Test heating by setting mode to HEATING and raising setpoint above room temperature.
Prepare the Schlage Bridge for enrollment by installing a battery and verifying its status.
Enroll the thermostat into the Schlage Bridge by holding them close and following on-screen prompts.
Check the ZNID value in Thermostat Info. A non-'000' value indicates successful enrollment.
Complete online setup by connecting the Bridge, logging in, and configuring climate settings.