EasyManua.ls Logo

Trane Symbio 800 - Page 11

Trane Symbio 800
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RT-SVX072A-EN
11
Digit 19 Ambient Control
0 = Standard
1 = Fahrenheit
Digit 20 Agency Approval
0 = None (cULus Gas Heater, see note)
1 = cULus
Note: Includes cULus classified gas heating
section only when second digit of
Model No. is a “F.”
Digit 21 Miscellaneous
0 = Unit Mounted Terminal Block
A = Unit Mounted Disconnect Switch
B = Unit Mounted Disconnect Switch with
High Fault SCCR
D = Unit Mounted Disconnect Switch with
Convenience Outlet
E = Unit Mounted Disconnect Switch with
High Fault SCCR and Convenience Outlet
Digit 22 Refrigeration Options
0 = Without Hot Gas Bypass
B = Hot Gas Bypass
Digit 23 Economizer Control
Options
C = Economizer Control with Comparative
Enthalpy
D = Economizer with Differential Dry Bulb
Z = Economizer Control with Reference
Enthalpy
W = Economizer Control with Dry Bulb
Digit 24 Damper Options
0 = Standard Dampers
E = Low Leak Economizer Dampers
U = Ultra Low Leak Economizer Dampers and
Ultra Low Leak motorized relief dampers
Digit 25 Power Meter
0 = None
1 = Power Meter
Digit 26 Efficiency Options
0 = Standard Efficiency Unit
H = High Efficiency Unit
Digit 27 Condenser Coil Options
0 = Air Cooled Aluminum Condenser Coil
J = Corrosion-Protected Condenser Coil
Digit 28 Rapid Restart
0 = Non-Rapid Restart
R = Rapid Restart
Digit 29 Miscellaneous
0 = Motors without Internal Shaft Grounding
A = Motors with Internal Shaft Grounding
Digit 30 Expansion Module
0 = None
E = Expansion Module
Digit 31 Miscellaneous
N = Ventilation Override Module
Digit 32 Service Options
0 = None
R = Extended Grease Lines
3 = Stainless Steel Sloped Drain Pan
4 = Stainless Steel Sloped Drain Pan with
Grease Lines
Digit 33 Cabinet Options
0 = Standard Panels
1 = Standard Panels with Double Wall
T = Hinged Access Doors
2 = Hinged Access Doors with Double Wall
U = IRU - with Standard Panels
3 = IRU - with Standard Panels with Double
Wall
W = IRU - with Hinged Access Doors
4 = IRU - with Hinged Access Doors with
Double Wall
Y = IRU with SST - with Standard Panels
5 = IRU with SST - with Standard Panels with
Double Wall
Z = IRU with SST - with Hinged Access Doors
6 = IRU with SST - with Hinged Access Doors
with Double Wall
Digit 34 Filter Monitor
0 = None
1 = Pre-Evaporator
2 = Pre-Evaporator and Final Filter
Digit 35 BAS/Communication
Options
0 = None
7 = Trane LonTalk Communication Interface
Module
8 = ModBus®
M = BACnet® Communication Interface (BCI)
Module
W = Air-Fi® Wireless
Digit 36 Isolators
8 = Spring Isolators
Digit 37 —Airflow
A = Downflow Supply/Upflow Return
B = Horizontal Right Supply/ Horizontal End
Return
C = Horizontal Right Supply/Upflow Return
E = Downflow Supply/Horizontal End Return
MMooddeell NNuummbbeerr DDeessccrriippttiioonn

Table of Contents

Other manuals for Trane Symbio 800

Related product manuals