Do you have a question about the Trane Symbio 700 Controller and is the answer not in the manual?
Model | Symbio 700 |
---|---|
Category | Controller |
Manufacturer | Trane |
Compatibility | Trane HVAC Systems |
Display | Color touchscreen |
Input Voltage | 24 V AC |
Enclosure Rating | IP20 |
Communication Protocol | BACnet, Modbus |
Operating Temperature Range | -40°F to 158°F (-40°C to 70°C) |
Explains the meaning of different advisory types used in the manual.
Highlights critical safety requirements for installation and servicing.
Lists other documents for Symbio 700 and Precedent systems.
Details the physical connections for inputs and outputs on the controller.
Explains how to configure the Symbio 700 system.
Describes the LCD display and navigation buttons for unit control.
Covers setup and editing using the Trane Symbio Service app.
Provides step-by-step instructions for connecting via Bluetooth.
Describes the controller's startup process and self-checks.
Details system responses to thermostat inputs during cooling.
Explains fan speed modulation based on space temperature.
Describes fan speed control for VVZT and CVZT systems in cooling.
Method to save energy by adjusting discharge air temperature setpoints.
Modulates fan speed to maintain duct static pressure.
Describes unit operation in heating mode with various heat types.
Covers cooling operation objectives and primary sources.
Explains full airflow heating operation with maximum fan speed.
Feature to rapidly increase space temperature before occupancy.
Mode to rapidly decrease space temperature before occupancy.
Details initiation and termination based on dew point or humidity.
Explains dehumidification initiation via humidity input or humidistat.
Describes the operation of two-stage gas heating systems.
Details the control of two stages of electric heat.
Configuration types for economizer damper control.
Ensures minimum ventilation requirements are met.
Reduces outdoor air based on space CO2 levels.
Adjusts minimum and maximum ERM parameters for airflow tuning.
Enforces minimum ON and OFF timers for compressors.
Monitors compressor contactor status for safety.
Controls system based on occupied or unoccupied periods.
Allows temporary override of scheduled unoccupied periods.
Feature for immediate shutdown of all equipment devices.
Limits unit capacity based on various factors.
Allows direct control of unit capacity via external input.
Manages system response to emergency or ventilation requests.
User-selectable duration for operating modes.
Details unit operation for specific configurations in test mode.
Tracks statistical data for unit components and run times.
Diagnoses issues related to compressor proving input.
Monitors and responds to low pressure cutout events.
Addresses issues with inter-module communications.
Details responses when sensor values are out of range.
Covers safety functions and responses for compressor failures.
Lists failures related to the ERM supply fan.
Diagnostics derived from Modbus ignition controller data.
Failure modes and system responses for economizer cooling.
Provides tables for multi-speed/ERM and variable speed fan speeds.
Details compressor staging response to thermostat signals.
Explains condenser fan operation for various unit types.
Lists supported diagnostics and their alarm relay functionality.
Defines how active space setpoints are calculated and validated.
Configures independent cooling and heating setpoints.