13
SPECIFICATIONS
Compressor Shutdown Protection (Auto Reset):
Stops Compressor 148 C (298 F)
Allows Compressor Start 90 C (194 F)
Bulb Mode:
Evaporator Fan Speed Settings Flow High: High speed only
Flow Low: Low speed only
Flow Cycle: Fans will cycle between low and high speed every 60 minutes
Defrost Termination Temperature Setting 4 to 30 C (40 to 86 F)
PHYSICAL SPECIFICATIONS
Fresh Air Exchange Venting System (Adjustable):
MAGNUM+ 0 to 225 m
3
/hr (0 to 168 ft
3
/min.) @ 60 Hz
0 to 185 m
3
/hr (0 to 139 ft
3
/min.) @ 50 Hz
Evaporator Fan Blade Specifications:
MAGNUM+:
Diameter 355 mm (14.0 in.)
Pitch 25°
Number of Fans 2
Weight (net):
MAGNUM+ Base Unit 380 Kg (875 lb.)
Water-cooled Condenser-Receiver Option 13.6 Kg (30 lb.)