Truck Body Opening Dimensions
The following requirements must be followed for all T-90 series truck units:
• Truck body opening dimensions and mounting hole locations must be correct for proper unit installation.
• Gasket sealing surface of 50.8 mm (2.00 in.) wide is required around unit opening. This surface must be flat within
6.4 mm (0.25 in.) and free of all rivets or bolt heads for proper gasket sealing.
• Unit mounting location must allow for adequate truck cab tilt clearance.
Figure 7. T-590 and T-690 Only — Front View of Truck Body Opening Dimensions From Outside of Truck
RCS1092-1
(4x)
349.3 mm
(13.75 in.)
15.9 mm
(0.625)
431.8 mm
(17.00 in.)
1305.1 mm
(51.375 in.)
652.6 mm
(25.69 in.)
619.2 mm
(24.38 in.)
1238.3 mm
(48.75 in.)
33.4 mm
(1.31 in.)
C
L
/
22.4 mm
(0.88 in.)
1
1.
Top of unit is to be mounted flush with top of cargo box when possible. Top of evaporator is to be positioned 25.4 mm (1.00 in.) below
ceiling. Dimension from the top of cargo box to evaporator cutout may vary depending on type of box, truck cab tilt clearance, etc.
T-590 through T-690 series units minimum dimensions = 107 mm (4.25 in.).
DDiimmeennssiioonnss