40
TK 56700-1-IM-EN
Steel or Aluminum Tank
IImmppoorrttaanntt:: Safety precautions must be followed. Refer to FFuueell SSyysstteemm CCoommppoonneenntt IInnssttaallllaattiioonn HHaazzaarrddss located in
the SSaaffeettyy PPrreeccaauuttiioonnss section of this manual before proceeding.
NNoottee:: The fuel pickup tube supplied in the installation kit will not be needed when also installing an optional Thermo
King aluminum fuel tank. The aluminum tank is already equipped with fuel inlet, fuel outlet and vent fittings.
EEPPAA CCOONNFFOORRMMAANNCCEE:: The fuel tank must have a label on the fuel inlet (fill spout) stating ULTRA-LOW-SULFUR FUEL
ONLY”. Verify label is present. If not present, order label 93-1184 and install on tank. Reference 40 CFR 1039.104(e)/
1039.135
IIMMPPOORRTTAANNTT IINNSSTTAALLLLAATTIIOONN TTIIPPSS
BEFORE drilling any holes, check for internal baffles inside the tank.
PRIOR to installation, remove protective caps from ends of pickup tubes.
DO NOT apply any type of sealant material to the fuel pickup tube assembly. Doing so will result in plugged fuel
lines.
NNoottee:: Use a magnet, grease or special hole saws/drills that will minimize debris from entering the fuel tank. Thoroughly
clean and flush the tank to remove any debris.
FOLLOW THE INSTALLATION INSTRUCTIONS INCLUDED WITH THE FUEL PICKUP TUBE
Figure 28. Typical Steel or Aluminum Fuel Tank Installation Shown
2
1
RCS1103-1
1. Return Fitting 2. Supply Fitting