RT-SVX23E-EN 21
Installation
WARNING
Heavy Objects!
Do not use cables (chains or slings) except as shown. Each of the cables (chains or slings) used
to lift the unit must be capable of supporting the entire weight of the unit. Lifting cables (chains
or slings) may not be of the same length. Adjust as necessary for even unit lift. Other lifting
arrangements may cause equipment or property-only damage. Failure to properly lift unit may
result in death or serious injury. See details below.
WARNING
Improper Unit Lift!
Test lift unit approximately 24 inches to verify proper center of gravity lift point. To avoid
dropping of unit, reposition lifting point if unit is not level. Failure to properly lift unit could
result in death or serious injury or possible equipment or property-only damage.
Table 1. Maximum unit & corner weights (lbs) and center of gravity dimensions (in.)
Unit
Maximum Model
Weights
(a)
Corner Weights
(b)
Center of Gravity (in.)
Tons Model No. Shipping Net A B C D Length Width
3 WSC036E 589 514 177 107 113 117 29 20
4 WSC048E 600 525 181 109 115 119 29 20
5 WSC060E 825 682 228 177 114 163 38 24
6 WSC072E 835 740 235 196 140 168 40 22
WSC090E 902 804 255 217 153 180 41 22
10 WSC120E 1431 1219 355 333 257 274 48 28
(a) Weights are approximate.
(b) Corner weights are given for information only.
Figure 12. Corner weights