INSTALLER'S GUIDE
18-HH08D10-2 Page 13
Pictorial Diagram No 3
COMFORT SENSOR CONNECTION DIAGRAM
Figure 13
1
2
5
6
S1
S2
B
R
S1
S2
R
B
SYSTEM CONTROLLER
(ZSASSMAL012)
DATA
DATA
24VAC
COM
ZUSTATALP52 & ZUSTATALS51
COMMUNICATING SENSOR
COMMUNICATION
TERMINAL
BLOCK
NOTE 1 - MULTIPLE COMMUNICATING COMFORT SENSORS MAY BE "DAISY-CHAINED' AS SHOWN
OR HOME RUNNED TO THE SYSTEM CONTROLLER IN A ZONED SYSTEM
3
4
RS1
RS2
⎬
TO ADDITIONAL COMMUNICATING
COMFORT SENSORS IN ZONED
SYSTEMS (SEE NOTE 1)
REMOTE ANALOG
SENSOR
ZZSENSAL011
(OPTIONAL)
ZUSTATALMS2
MASTER SCHEDULER
TB1
Figure 12
ZONE/BYPASS CONTROL CARD SWITCH SETTINGS
OFF
ON
TB1
DSW
OPEN
CLOSE
DUMP
1
2
3
1
2
3
24V
COM
DUMP
(IF APPLICABLE)
CLOSE
OPEN
24 VAC (R)
COM (B)
ZONE/BYPASS CONTROL CARD
ZZCARDAL0100
USE DIP SWITCH TO SET MAXIMUM PERCENT OF EQUIP-
MENT CFM TO BE SUPPLIED TO EACH INDIVIDUAL ZONE
ZONE DAMPER DIP SWITCH
BYPASS
DAMPER
PERCENT%
PERCENT
WEIGHT
ZONE
DAMPER
PERCENT%
123
7 100 ON ON ON 50
685OFFONON42
565ONOFFON32
450OFFOFFON25
340ONONOFF20
2 30 OFF ON OFF 15
1200NOFFOFF10
0
(DE-ACTIVATED)
OFF OFF OFF
(DE-ACTIVATE-
D)