TP-701 / TP-701P Q&A
Confidential TO: FROMM HOLDING AG
Page 8 of 23 8/19/2008
IV. Too much or insufficient strap in the pool box lead to short feed problem
1. Please refer to manual Part I P24 how to adjust the strap amount in accumulator
2. When insufficient strap is due to not enough pressure, please increase the pressure.
2.1 Adjust the Spring (T7-1-20120) to increase the pressure.
2.2 Please check if the Spring (T7-1-20120) is over stretched? If so, please replace
with a new one.
2.3 Assistant Roller (T7-3-20160 or T7-3-20162) is worn or too much dust on it and
reduce pressure.
3. Unsmooth of Balance Bar (T7-3-10140 or T7-3-10141) may cause poor strap
accumulation. (may conflict with Accumulator Box Cover (T7-3-30110))
T7-3-20160
T7-3-10140
T7-3-10110
T7-1-20120