Operating Guide | TS-700 Series
17
PARAMETER
FUNCTION
OPTIONS
C26
CAUTION:
Changing
these
parameters will
affect the
indicator’s
performance.
Standstill time
0 = quick
1 = medium
2 = slow
C27
Standstill range
1 = 1d 2 = 2d
5 = 5d 10 = 10d
(d = division)
C28
CAUTION:
Changing
these
parameters will
affect the
indicator’s
performance.
Digital filter
To compensate
for unstable
loads on the
weighing
platform (for
example, animal
weighing).
0 = close dynamic filter
1 = 1 digital filter strength
2 = 2 digital filter strength
3 = 3 digital filter strength
4 = 4 digital filter strength
5 = 5 digital filter strength
6 = 6 digital filter strength
C29
CAUTION:
Changing
these
parameters will
affect the
indicator’s
performance.
Noise filter
0 = disable noise filter
1 = 1 digital filter strength
2 = 2 digital filter strength
3 = 3 digital filter strength
C30
Format of date
print out
0 = yy.mm.dd
1 = mm.dd.yyyy
2 = dd.mm.yyyy
3 = yyyy.mm.dd
C31
OPTIONAL
output setting
0 = 0~5Voutput
1 = 4~20mA output
C32
RESERVED
-------