Operating Guide | TS-700 Series
A-14
Appendix For Scale Technicians
SERIAL INTERFACE PC COMMAND
REQUESTS
RS232COM serial interface can receive simple
ASCII commands.
Command word and role as follows:
Command
Name
Function
T
TARE
Save and clear tare
Z
ZERO
Zero gross weight
P
PRINT
Print the weight
R
G.W/N.W
Read gross weight or net weight
C
Kg/lb
Kg/lb conversion
G
G.W
Check gross weight at net weight mode
PRINT RECEIPT DATA FORMAT
Print Format
ID.NO..................... 004 (sequential #)
Date: ...................... XX.XX. XX (yy.mm.dd)
Time:...................... XX.XX.XX (hh.mm.ss)
GROSS.................. NNNNNN lb/kg
TARE ..................... NNNNNN lb/kg
NET ....................... NNNNNN lb/kg