EasyManua.ls Logo

Triner Scale TS-700 Series - Error Codes and Troubleshooting

Triner Scale TS-700 Series
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Guide | TS-700 Series
A-15
Appendix For Scale Technicians
Error Codes
ERROR
CAUSE
SOLUTION
uuuuuu
1. Overloaded
condition.
2. Wrong
connection at
load cell.
3. Defective load
cell.
1. Reduce the weight.
2. Check load cell
connection
3. Inspect load cell. Check
the input and output
resistance of load cell.
nnnnnn
1. Calibration is
incorrect.
2. Bad connections.
3. Defective load
cell.
1. Check scale is resisted
or not, foot is kept level
or not.
2. Check load cell
connection.
3. Check input and output
resistance of load cell.
ERR1
Overweight
calibration error.
Incorrect weight
input or incorrect
weight on
weighing
platform.
1. Input weight correctly
during calibration.
2. Place correct weight on
weighing platform.
ERR2
Underweight
calibration error.
Incorrect weight
input or incorrect
weight on
weighing
platform.
The calibration weights
Minimum is 10% of Max.
cap. Recommend 60%-
80% of Max. Cap.
ERR3
During
calibration, the
input signal is
negative.
Check all connections.
Check load cell.
If connections and load
cell are okay, PCB
needs replacing.

Other manuals for Triner Scale TS-700 Series