If the appliance is being connected directly to the mains supply, an omnipolar circuit
breaker must be installed with a minimum gap of 3 mm between the contacts.
The installer must ensure that the correct electrical connection has been made and that it
complies with safety regulations.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by authorised technicians only.
IMPORTANT!
The connection of this cooktop must be carried in accordance with the
current versions of the following:
Gas Safety and Measurement Regulations 2010
AS/NZS 3000 Wiring Rules
Electricity Safety Regulations 2010
The installation instructions within this user manual
Before connecting the cooktop, make sure that the supply voltage marked on the
rating plate corresponds with your mains supply voltage.
The appliance must be wired into a 30A double pole switched fused spur outlet, having
3mm contact separation and placed in an easily accessible position adjacent to the
appliance. It should not be located above the appliance and no more than 1.25m
away from it.
The spur outlet must still be accessible even when your cooktop is located in its
operating position.
Cable type: H05 VVF 3 core x 4mm2
The cable can be looped if necessary, but make sure that is not kinked or trapped
when the cooktop is in position. Care must be taken to avoid the cable being in
contact with hot parts of the appliance.
4.5 CONNECTING THE MAINS SUPPLY CABLE
IMPORTANT!
This cooktop requires hard-wire connection. The cooktop must NOT be connected to
the mains supply by means of a 10A or 15A plug and socket.
The appliance must be wired into a 30A double pole switched fused spur outlet,
having 3mm contact separation and placed in an easily accessible position
adjacent to the appliance. It should not be located above the appliance and no
more than 1.25m away from it.