12
CONTACT DEGASSING SYSTEM
NOTE: THE UNIT IS SUPPLIED WITH 1 1/4” - 1” REDUCERS FOR THE WATER
CONNECTIONS TO ALLOW THE USE OF 1” PIPING
Should the plantroom be below the level of the pool, the system must run
on a 24 hour cycle, as the head of water created could cause a leak through
the vent valve and find its way into the plantroom via the waterpot. If the
plant has to be closed down for any reason, close the ½ “ compact manual
valve provided. If the plantroom is above the pool level these precautions
need not apply.
Note! The automatic level control valve is not a 100% shut off valve.