Specifications
Function
Range
Resoluti
on
Accuracy ±(% of
reading+digits)
AC True RMS
Current
200.0A
100mA
±(3% + 5 digits)
Over Rang Protection: Maximum input 200A; Frequency Response: 50 to 60Hz
AC True RMS
Voltage (Auto Sense)
1.000 to 6.000V
1mV
±(1.2% + 5 digits)
60.00V
10mV
±(1.2% + 2 digits)
600.0V
100mV
1000V
1V
±(1.5% + 2 digits)
Input Impedance:10MΩLow Input Impedance Test Voltage: ~3KΩ MAX 600V
AC;
Accuracy Specified from +3.0% of rdg +8digits;
Over Rang Protection: 1000V rms
Frequency Response: 50 to 1000Hz(sine wave), 50/60(all wave)
DC Voltage
(Auto Sense)
6.000V
1mV
±(0.9% + 5 digits)
60.00V
10mV
±(1.0% + 2 digits)
600.0V
100mV
1000V
1V
±(1.2% + 2 digits)
Input Impedance: 10MΩ; Low Input Impedance Test Voltage: ~3KΩ MAX 600V
DC; Accuracy Specified from+3.0% of rdg +8digits; Over Rang Protection: 1000V
Resistance
600.0Ω
0.1Ω
±(1.0% + 4 digits)
6.000kΩ
±(1.5% + 4 digits)
60.00kΩ
10Ω
600.0kΩ
100Ω
6.000MΩ
1kΩ
±(2.5% + 4 digits)
60.00MΩ
10kΩ
±(3.5% + 4 digits)
Over Rang Protection: 300V rms