Page 5
* Operating Frequency (RF): 400KHz to 500KHz
* Operating Frequency (AF): 800Hz to 2400Hz
* Output Voltage (RF): adjustable from approx. 5Vpp to 30Vpp (open circuit)
* Output Voltage (AF): xed, approx 10Vpp (open circuit)
* Tracer Tone: Warble or Pulsed, High or Low Pitch
* TrueTrace: Tracer Tone changes Cadence (from approx 2Hz to approx 7Hz) when leads are ‘shorted’ by
less than 1,000 Ohms
* Continuity Test: Detects Continuity up to 5,000 Ohms, sounds beeper
* Voltage Test: Sounds beeper, Flashes LED
AC: Detects voltage from approx. 30VAC to 250VAC (50/60Hz)
DC: Detects Positive applied to Red Test Lead from 40VDC to 250VDC
* Acceptable AC (50/60Hz) or DC voltage on wire to be traced: 0 to 250V
* Safety: Designed to tolerate 250V AC/DC CAT II without damage
* Test Leads and Accessories: 2’ and 5’ red and black test lead sets. 1 set of red and black pointed probes.
1 set of red and black at probes. 1 set of red and black alligator clips. 1 set of red and black screw-on
alligator clips.
* Battery: 9 volt alkaline
* Battery Test: Flashes green LED to indicate good battery
* Battery Life: Approx 200 Hours in Trace Mode (Alkaline Battery)
* Self Powered Voltage Range: approx 30VAC to 250VAC, 60Hz
* Fuses: Two 0.5A / 250VAC, 5 x 20mm
* Size: 3 1/2” x 4 1/2” x 1 1/2”
* Weight: Less than 7 ounces (including battery, not including test leads)
4: Specications for HotWire Fox