6
Administrator Setup
Once the B051-000 has been installed, the Administrator must prepare the unit for user
operation by setting the network parameters and adding users.
Web Browser
By default, the B051-000 is set to have its IP address assigned automatically via DHCP
server. If it is connected to a network without a DHCP server, it boots with a default IP
address. On IPv4 networks, the default IP is 192.168.0.60. If it is on an IPv6 network, the
default IP address is determined by the B051-000’s MAC address. For example, if the MAC
address is 00-10-74-13-81-01, the IPv6 address is FE80:0:0:0:0010:74FF:FE13:8101.
The parts of the IP address that are in bold and underlined are xed.
First Time Setup
Network Setup - IP Address Determination
If you are an administrator logging in for the rst time, you must access the B051-000
in order to give it an IP address to which users can connect. You can do this via Web
Browser, the IP Installer utility, or the non-browser Windows or Java Client applications.
1. Enter the unit’s IP address into your web browser.
2. You may be prompted by a screen stating that there is a problem with this website’s
security certicate. Click on the option to continue to the website anyway. (See Web
Browser Login section for details on installing the security certicate)
3. You will be brought to a login page. Enter the default Username (administrator), and the
default Password (password). The Admin Utility Main Page will open upon entering the
Username and Password.
12-003 932851-EN.indd 6 8/7/2012 8:59:43 AM