3
MicroIQ Electronic Lock Programming Guide
Programming a New Master Code
Warning: Do not set your Master Code to 1-2-3-4-5. Doing so will
erase all existing Access Codes and reset User ID 1-1 to
Access Code 1-1-1-1-1.
If a valid Master Code is entered, the green, red, and yellow
LEDs will ash.
If an invalid Master Code is entered, the red LED will flash 3
times, and the keypad will exit programming.
Once the new Master Code is programmed, the 1-2-3-4-5 Factory
Code becomes invalid.
Note: All Access Codes remain the same when a new Master Code is
programmed.
1. With the lock in either unlocked or locked position, press and
The keypad will enter programming mode, and the green LED
will light up.
2. Enter your 5-digit Master Code
If the code is entered correctly, the green LED will light up.
Proceed to step 3.
If no code is entered within 10 seconds, or if the code is entered
incorrectly, then the red LED will flash 3 times, and the keypad
will exit programming mode.
3. Press and hold the Program Button for 5 seconds.
The keypad will enter programming mode. The red LED will
flash once, and then the green and yellow LEDs will light up.
4. Enter the desired 5-digit Master Code.
MY MASTER CODE: __ - __ - __ - __ - __
Programming Instructions
hold the Program Button
(located below the #3 button) for 5
seconds.