Power Shower
5
IMPORTANT
The shower installation must be carried
out by a suitably competent person and
in sequence of this instruction book.
Please read through the whole of this
book before beginning your installation.
DO NOT use jointing compounds on any
pipe fittings for the installation.
Switch off immediately at the isolating
switch if water ceases to flow during use.
DO NOT operate the shower outside the
guidelines laid out in ‘site requirements’.
SPECIFICATIONS
Hot Water Temperature
Maximum temperature 65°C.
A stored water temperature of 60°C is considered
sufficient to meet all normal requirements and
will minimise the effects of scale in hard water
areas.
Temperature Control
To obtain the maximum performance, this unit
should be installed, operated and maintained as
instructed in this book. Optimum performance
is achieved with water supplies of 15°C cold and
60°C hot and with nominally equal pressures.
Maximum static inlet pressures
100 Kpa (1 bar) or 10m (supplies must be
gravity fed at nominally equal pressures).
Minimum static inlet pressure
0.75 Kpa (0.0075 bar) or 75mm (required to
prime the integral centrifugal pump).
Maximum total head 2m
This is the vertical distance that you are able to
pump the water.