Sleeve cleaning
Mineralsinthewaterslowlyformacoatingonthesleeve.Thiscoatingmustberemovedbecauseitreducesthe
amountofUVlightreachingthewater,therebyreducingdisinfectionperformance.Theneedtocleanthesleeve
willbeindicatedbyalowUValarm(flashingredindicatorlightbesidethesensoroncontrolpanel-seeControl
Panelsectionfordetails).
Note:LowUValarmsareforPro&PlusSeriesonly.IfyouownaBasicmodel,pleasecleanthesleeveregulary
(3-4timesperyear,ormoreoftendependingonwaterquality).
Whenonlycleaningisrequired,followtheinstructionsbelowandre-installthecurrentlamp.
Lamp replacement
TheamountofUVlightcreatedbythelampdecreasesovertime,requiringthatthelampbereplaced.The
systemwillautomaticallynotifyyouwhenitistimetoreplacethelamp(thelampshouldlastapproximately24
months).Ifthelamprequiresreplacement,followtheinstructionsbelowandinstallanewlamp.NOTE:TheUV
systemisdesignedtooperatecontinuouslyandshouldnotbeshutoffforshortperiodsoftime,suchasovera
periodoflessthanthreeweeks.
Equipment required:
SLEEVE CLEANING & LAMP REPLACEMENT
Cloth must be
soft, lint-free, and
chemical-free. No
clean-wipes.
Scale remover
such as CLR
TM
or
Lime-Away
TM
.
#2 Phillips
screw driver
Cottom swab. Clean cotton, latex
or plastic gloves
are prefered.